REGISTRATION CHARACTERISTICS OF PET MELINEX-E SOLID STATE NUCLEAR TRACK DETECTORS (SSNTD)
TO HEAVY IONS
*

GHANIM, E.H.(1), EL-SAMMAN, H.M.(2), HUSSEIN, A.(2)
and TRETYAKOVA, S.P.(3)

(1) Basic Sciences Department, Faculty of Industrial Education, Beni-Sueif University, Beni-Sueif , Egypt, (2) Physics Department, Faculty of Science, Menofia University, Shebin El-Koam, Egypt and (3) Joint Institute
for Nuclear Research (JINR), Dubna, Russia.

Key words: SSNT detectors, PET Melinex-E, Heavy ions.

خصائص تسجيل الأيونات الثقيلة فى كاشف الحالة الجامدة للأثر النووى
البولى اثيلين تريفثالات (ميلينكس–
E)

عماد حامد غانم و حسين محمود السمان و عبد العظيم المرسى حسين
و سفيتلانا تريتياكوفا

خلاصـة

يعتبر العامل الرئيسى المؤثر فى حساسية كواشف الحالة الصلبة للأثر النووى لتسجيل الايونات الثقيلة هو سرعة الحفر الكيميائى ( V) و التى تبين اعتمادها على بعض العوامل مثل طول الأثر النووى وبالتالى طاقة الأيون الساقط و كذلك تركيز المحاليل الكيميائية المستخدمة فى المعالجة و درجة حرارتها.

تبين من الدراسة أن اعتماد VT على درجة الحرارة يخضع الى معادلة أرهينيوس حيث تم حساب طاقة التنشيط اللازمة لعملية الحفر الكيميائى للرواصد المستخدمة وكانت قيمتها 0.77  
ا.ف، بينما اعتمادها على تركيز المحلول يمكن تمثيله بمعادلة أسية. ومن ثم تم استخدام رواصد البولى اثيلين تريفثالات فى دراسة تسجيل الأثر النووى للنظير إكسينون
-129 بطاقة 129 م.ا.ف بزوايا سقوط مختلفة و كذلك الآثار الناتجة عن نواتج الإنشطار النووى التلقائى المنبعث من مصدر كاليفورنيوم-252 تحت ظروف مختلفة.

ABSTRACT

The main parameter that affects the response of an etched track detector toward the registration of an incident ion is the track etch rate (VT). VT was measured through projected track length and the dependences of VT  on different parameters; etchant concentrations (C) and temperatures (T), were investigated. The results showed that VT of polyethylene terephthalate (PET) Melinex-E
(C10H8O4) depends upon the etchant temperature (T) through an Arrhenius equation while the dependence of VT on the etchant concentration was found to obey the relation VT = A Cn. The activation energy of etching (ET) for the studied Melinex-E detector was calculated where an average value ET = 0.77 ± 0.03 eV was extracted. Track registration characteristics have been carried out. The registration properties of PET Melinex-E SSNT detectors were also studied with respect to different parameters. The irradiation facilities were performed with
the 129Xe+8i = π/2, 30o) and 252Cf fission fragments (θi = π/2, 60o). The results of these studies were discussed in the frame work of nuclear track formation.


 

 

 

 

 

اهداف المركز
أ
هداف المركز

الهيكل التنظيمى
الهيكل التنظيمى


الخدمات
الخدمات


المجلة
المجلة


الدورات التدريبية
الدورات التدريبية


منح الزمالة
منح الزمالة


العنوان: 9 شارع ملاعب الجامعة   الدقى جيزة جمهورية مصر العربية          رقم بريدى:12311
تليفون: 3370588 - 3370569                                    تليفاكس: 3371082
البريد الإلكتروني : merrcac@yahoo.com